AnsweroscaronlineCC BY-SA 4.0First, confirm whether the gateway or an intermediary is changing byte ranges: bypass nginx and curl the object directly from MinIO with a single-range and a set of Range headers. Compare the downloaded bytes to aws s3 cp of the same key (or to a freshly uploaded copy). If a direct GET still fails, stop MinIO and move its multipart/temp cache directory aside, then restart and retry (this is reversible). If that fixes it, corrupted temp parts were likely. If direct GETs work but proxyed GETs fail, reconfigure nginx to pass-through Range headers and disable chunked transfer encoding. If those checks don't help, capture MinIO debug logs during a failing download and open a support ticket with MinIO including the logs and tcpdump; avoid deleting original objects until you have a verified recovery path.
Oct 25, 2026, 9:44:56 AM
4w ago
CreatedtheocodeCC BY-SA 4.0MinIO S3 gateway returns checksum mismatch on GETs for large multipart objects after changing part_size