Diagnostic step 1
Apply a reversible interim: disable LRO/GRO/TSO inside guests on affected hosts (ethtool -K eth0 gro off lro off tso off) and test traffic. This is reversible per-VM.
Generated Oct 18, 2026, 9:45:27 AM
Apply a reversible interim: disable LRO/GRO/TSO inside guests on affected hosts (ethtool -K eth0 gro off lro off tso off) and test traffic. This is reversible per-VM.
Schedule maintenance to rollback NIC firmware on affected hosts or apply vendor firmware patch; test on a single host first.
Collect vmkernel logs, ethtool stats, and switch port counters while reproducing; open vendor and VMware SRs with evidence.