FULL AI ANALYSIS

Docker overlay network experiences severe packet loss and retransmits after NIC firmware update — large VXLAN packets fragmented by offload regression

Generated Oct 17, 2026, 9:26:12 AM

Analysis summary

The timing (immediately after NIC firmware/driver update) combined with the pattern (large flows over VXLAN fail while small packets succeed) strongly suggests an offload/firmware regression where the NIC or its driver mishandles GSO/GRO/GSO for tunneled (VXLAN) packets. Disabling host offloads improves but does not fully fix, indicating host driver/firmware is a prime suspect. Switch MTU mismatch is less likely since switch logs show jumbo enabled and migration didn't remove the issue, but MTU remains a contributing factor. Docker overlay config adjustments reduced impact but did not restore baseline, consistent with a lower-level offload problem.

Possible causes

NIC firmware/driver regression after vendor update that incorrectly handles GSO/GRO for tunneled VXLAN/Geneve packets, causing oversized or malformed frames to be dropped

85%

Switch MTU or jumbo frame path misconfiguration causing fragmentation or dropped large frames under high load (contributing factor)

45%

Docker overlay network MTU misconfiguration combined with bonded interface settings causing inconsistent fragmentation behavior across hosts

35%

Kernel bug in GSO/GRO handling for encapsulated packets (less likely given correlation with vendor firmware update)

25%

Suggested fixes

1

Diagnostic step 1

Capture packet traces at multiple points: physical interface on host A, vxlan0 (or docker_gwbridge) on host A, and the container interface; repeat on host B for the same flow. Compare packet sizes and fragmentation to pinpoint where packets are lost or malformed. Sanitize any payloads before sharing externally.

2

Diagnostic step 2

Temporarily disable hardware offloads on both hosts (ethtool -K <iface> tso off gso off gro off) and re-run throughput tests. This is reversible and often isolates offload-related bugs. If disabling offloads restores throughput, prioritize NIC firmware/driver rollback or vendor escalation.

3

Diagnostic step 3

As a reversible mitigation, lower overlay MTU to 1500 cluster-wide and verify if observed stability is acceptable; document performance delta. This avoids jumbo-frame fragmentation on the overlay path but reduces maximum throughput.

4

Diagnostic step 4

Test with the previous NIC driver/firmware on a staging host (rollback) to validate whether the update introduced the regression. Only rollback in a controlled maintenance window with backups of host configuration.

5

Diagnostic step 5

If tests indicate a NIC vendor regression, collect and submit to vendor: sanitized tcpdumps from physical and vxlan interfaces, ethtool -k output, driver and firmware versions, kernel dmesg lines and reproduction steps. Avoid including customer data in these logs; replace IP addresses and hostnames if necessary. Escalate to NIC vendor engineering and provide reproduction on isolated hosts. If vendor cannot provide a fix quickly, consider keeping offloads disabled as an interim workaround while tracking CPU impact and planning for scheduled firmware rollback.