Diagnostic step 1
Capture IPv6 flow (tcpdump -n -i <uplink> ip6) for an affected client during a failure and note the source address used and the outgoing interface.
Generated Oct 19, 2026, 9:33:36 AM
Capture IPv6 flow (tcpdump -n -i <uplink> ip6) for an affected client during a failure and note the source address used and the outgoing interface.
Run 'ip rule show' and 'ip -6 route show table all' to verify which table is used for the client's source prefix and check the per‑table default route.
Temporarily disable rp_filter: echo 0 > /proc/sys/net/ipv4/conf/all/rp_filter (and per‑iface) to see if replies are accepted; revert after test. Use sysctl for persistence only after verifying.
Force correct source selection for that client subnet by adding a specific route with 'ip -6 route add default via <gw> dev <if> src <client::prefix>' or set 'from <prefix> lookup <table>' rules so replies follow the same path.
If asymmetric routes are unavoidable, consider SNAT for IPv6 (NAT66) or using stateful connection tracking on the edge (or request upstream ACL changes) to ensure reverse packets return over same link, then verify with repeated downloads and tcpdump.