Diagnostic step 1
Keep the new VLAN offline and reproduce in maintenance window. Capture a continuous packet trace on the router uplink (mirror trunk) while toggling VLAN 20 to see if ARP/LLDP/BC packets flood.
Generated Oct 3, 2026, 12:35:03 AM
Keep the new VLAN offline and reproduce in maintenance window. Capture a continuous packet trace on the router uplink (mirror trunk) while toggling VLAN 20 to see if ARP/LLDP/BC packets flood.
On the switch, verify trunk configuration: show interfaces trunk to confirm VLAN 20 is allowed on uplinks and that native VLAN settings match the router. Fix mismatches and re-test.
Enable port isolation / storm-control on affected access ports to limit broadcast/flood rate while debugging, preventing office-wide outage.
Temporarily move one host from VLAN 20 to a spare trunk port directly on the router and test connectivity — isolates switch vs router problem.
Inspect switch STP state per-port (show spanning-tree) and identify any rapid topology changes; if an unexpected downstream device is present, physically isolate it and retest.) If logs continue to show MAC table corruption, roll back to the previous firmware and open a vendor support case (escalate if evidence of memory/MAC table corruption).