ESXi VMs stop receiving external TCP packets after NIC firmware update; vmxnet3 RX rings appear frozen
Environment
vSphere ESXi 7.0 hosts with Broadcom 10Gb NICs received vendor NIC firmware and VIB driver updates. Multiple Linux VMs (various distros) running vmxnet3 report inbound traffic stalls under sustained load; host uplinks remain carrier-up. Affected VMs on multiple hosts exhibit the same issue.
Symptoms
VMs show interfaces up but external TCP connections stall (no new packets reach VM). Host vmkernel.log contains vmxnet3 Rx timeout and offload errors. Restarting the VM restores connectivity for a short time. Issue reappears under sustained bidirectional traffic.
Observations
Inside guest, ethtool -S shows RX descriptors not advancing; disabling LRO/GRO in the guest restores traffic immediately. Rolling back NIC firmware on one host resolved the issue for VMs on that host. Guest vmxnet3 driver versions match recommended VMware tools release. Physical switch shows increased TX errors on affected host port.
Already attempted
Disabled LRO/GRO/TSO in guests (temporary fix), reinstalled VMware Tools, rebooted hosts, rolled back firmware on a single host (worked), gathered vmkernel and host logs, opened vendor SR.
Question
Is there a safe, reversible interim configuration to restore stable VM networking across hosts cluster-wide, and what is the recommended permanent remediation path?
Verified community troubleshooting
Start with a low-risk, reversible workaround: disable LRO/GRO/TSO inside the affected guest(s) (ethtool -K eth0 gro off lro off tso off). That immediately unblocks traffic and is easy to rollback. Meanwhile, test a firmware rollback or vendor firmware patch on a single maintenance host — rolling back fixed one host in our environment. Capture vmkernel logs and NIC counters, and open SRs with vendor/VMware so they can supply a permanent firmware/driver fix. Note disabling offloads increases CPU and may lower throughput, so plan to re-enable once vendor patch is applied.
Incident analysis
Most likely causes
Summary
Suggested Fixes
Continue troubleshooting
Related troubles
Matched from the title, description and tags
- Virtualization30% match
ESXi guest VM stops receiving external TCP traffic after host kernel hotpatch — vmxnet3 RX stalls while interface stays up
Open0 answers - Networking21% match
Docker overlay network experiences severe packet loss and retransmits after NIC firmware update — large VXLAN packets fragmented by offload regression
Open0 answers - Linux21% match
Linux kernel logs NETDEV WATCHDOG and igb driver drops packets after enabling GRO on high-throughput gateway
Open1 answer - Networking20% match
Home mesh Wi‑Fi: Bonjour/mDNS discovery stops on 5 GHz SSID after vendor firmware update
Open1 answer